Precision Power Analyzers
LMG671: The successor of the LMG670 with 10.1" touch display and USB3.0
Precision Power Analyzers
LMG671 1 to 7 Channel Power Analyzer
Frequency:
DC-10 MHz
|
Accuracy:
0.025%
|
Ranges:
30 mV - 1000 V / 5 mA - 32 A
Applications:
Frequency converter, Switching Power Supplies, Aviation Compliance, Lighting Engineering, Electric drive systems, White Goods, Research / Laboratories, Consumer Electronics, Power Generation, Transport, Inductive Components & Cores, Test Bench Design & Development, Ultra-high-speed Machines
LMG641 1 to 4 Channel Power Analyzer
Frequency:
DC-10 MHz
|
Accuracy:
0.025%
|
Ranges:
30 mV - 1000 V / 5 mA - 32 A
Applications:
Frequency converter, Switching Power Supplies, Aviation Compliance, Lighting Engineering, Electric drive systems, White Goods, Research / Laboratories, Consumer Electronics, Power Generation, Transport, Inductive Components & Cores, Test Bench Design & Development, Ultra-high-speed Machines
LMG611 Single Channel Precision Power Analyzer as Compact Desktop Device
Frequency:
DC-10 MHz
|
Accuracy:
0.025%
|
Ranges:
3 V - 1000 V / 5 mA - 32 A
Applications:
Frequency converter, Switching Power Supplies, Aviation Compliance, Lighting Engineering, Electric drive systems, White Goods, Research / Laboratories, Consumer Electronics, Power Generation, Transport, Inductive Components & Cores, Test Bench Design & Development, Ultra-high-speed Machines
LMG671-ATE 1 to 7 Channel Power Analyzer optimized for rack-mounting
Frequency:
DC-10 MHz
|
Accuracy:
0.025%
|
Ranges:
30 mV - 1000 V / 5 mA - 32 A
Applications:
Frequency converter, Switching Power Supplies, Aviation Compliance, Lighting Engineering, Electric drive systems, White Goods, Research / Laboratories, Consumer Electronics, Power Generation, Transport, Inductive Components & Cores, Test Bench Design & Development, Ultra-high-speed Machines
Different power measurement channels for your LMG600 A, B, C or S?
Frequency:
DC-10 MHz, DC-500 kHz or DC-10 kHz
|
Accuracy:
0,025%, 0,04 % or 0,07%
|
Ranges:
30 mV - 1000 V / 5 mA - 32 A
Applications:
Lighting Engineering, Switching Power Supplies, Aviation Compliance, White Goods, Research / Laboratories, Consumer Electronics, Power Generation, Transport, Inductive Components & Cores, Test Bench Design & Development, Frequency converter, Electric drive systems, Ultra-high-speed Machines
Sensors
Sensors
Compliance Test Systems & Softwares
LMG Accessories
- LMG600 Accessories
- LMG500 Accessories
- LMG450 Accessories
- LMG95/95e Accessories
| Ordernumber | Product description |
|---|---|
| L6-ACC00-DE | LMG600 series manual in German |
| L6-ACC00-EN | LMG600 series manual in Englisch |
| L6-ACC-SYNC-2 | Sync cable for pair of two LMG600 |
| L6-ACC-SYNC-3 | Sync cable for pair of three LMG600 |
| L6-OPT-HDL2 | Handles for LMG610/640/670, 2 pcs. for front side |
| L6-OPT-HDL4 | Handles for LMG610/640/670, 4 pcs. for front and rear side |
| L6X1-OPT-HDL2 | Handles for LMG611/641/671, 2 pcs. for front side |
| L6X1-OPT-HDL4 | Handles for LMG641/671, 4 pcs. for front and rear side |
| L67-X-01 | 19 inch rack mount kit for LMG610 |
| L671-X-01 | 19 inch rack mount kit for LMG611 and LMG671 |
| L64-X-01 | 19 inch rack mount kit for LMG640 |
| L641-X-01 | 19 inch rack mount kit for LMG641 |
| L60-X-ADSE | Adapter for LMG600 series to connect sensors and current clamps |
| L6-ACC05 | Transport case for LMG67x/64x and accessories |
| Order No. | Product Description |
|---|---|
| L50-Z00 | LMG500 manual, German or English |
| L50-Z01 | 19″-Mounting kit for LMG500 |
| L50-Z04 | Carrying case for LMG500 and accessories (1-4 channels) |
| L50-Z05 | Carrying case for LMG500 and accessories (5-8 channels) |
| L50-Z13 | |
| Cable for coupling | |
| a second LMG500(for power measurement channels 5-8) | |
| (DSP extension modul possibly necesary, refer to L50-O10) using a LMG500 for channels 5-8 instead of the extension chassis LMG500-E | |
| L50-Z14 | Adapter for LMG500 to connect sensors and current clamps terminating with HD15-plug |
| HD15 to 4mm measuring inputs and DSUB9 sensor identification / supply, especially for L45-Z06, -Z10, -Z16, -Z26, -Z28, -Z29 | |
| L50-Z18 | Adapter for incremental speed sensor onto LMG500 measuring channel (I-Sensor input) |
| Pulses converted to analog voltage with +/-sign indicating sense of rotation | |
| short response time for graphical presentation to analyse extremely dynamic processes | |
| L50-Z19 | Adapter to synchronize |
| on fundamental frequency using a xA:1A current clamp (to be ordered separately), with settable low pass Filter 200Hz – 20kHz | |
| L50-Z318 | RS232 – Ethernet – converter, 10/100Mbit |
| external adaptor, all connectors will fixed at the LMG, power supply from LMG |
| Order No. | Product Description |
|---|---|
| L45-Z00 | LMG450 manual, German or English |
| L45-Z01 | 19″-Mounting kit for LMG450 |
| L45-Z02 | Carrying / tilting handle bar for LMG450 |
| L45-Z04 | Carrying case for LMG450 and accessories |
| Plastic foam material inside, outside material Aluminum, lockable, dimensions 25cm x 49cm x 38cm | |
| L45-Z09 | Adapter BNC to HD15 for isolating current sensors with voltage output; but no EEPROM |
| L45-Z13 | LMG450/500 master-slave cable, length 1m |
| connection of 2 pcs. LMG450 via Sync inputs for simultaneous measuring of more than 4 phases | |
| Possible couplings: | |
| LMG450 <-> LMG450 | |
| LMG450 <-> LMG500 (1-8 phase) | |
| LMG500 (1-8 phase) <-> LMG500 (1-8 phase) | |
| L45-Z18 | Adapter for incremental speed sensor onto LMG450 measuring channel (HD15 sensor input) |
| Pulses converted an analog voltage with +/- sign indicating sense of rotation | |
| Short response time for graphical presentation to analyse extremely dynamic processes | |
| L45-Z22 | Adapter safety plug to HD15 for isolating current sensors |
| with current output up to 1,2Apk; EEPROM for storage of scaling | |
| L45-Z318 | RS232 – Ethernet – converter, 10/100Mbit |
| external adaptor, all connectors will fixed at the LMG, power supply from LMG | |
| SSU4 | Supply unit for 1 to 4 pcs. PSU600 sensors and L45-Z29, |
| for use with LMG instruments | |
| LMG-Z-AMP | Artificial starpoint simulation for 3p-3w-systems |
| L5-Z03 | Cable for coupling of process signal interfaces (analogue and digital) between two LMG450 and/or LMG95 |
| (option L45-O3, L95-O3), exchange of measuring values for further computation with formula editor, e.g. calculation of efficiency | |
| L5-IOBOX-S | Adapter (also for DIN rail mount) from 25pol. SUB-D connector to screw cage connection for conductor cross sections up to 1,5mm x mm |
| incl. 2m cable for connecting adapter with one processing signal interface | |
| L5-IOBOX-F | Adapter (also for DIN rail mount) from 25pol. SUB-D connector to screw cage connection for conductor cross sections up to 1,5mm x mm |
| incl. 2m cable for connecting adapter with one processing signal interface |
| Order No. | Product Description |
|---|---|
| L95-Z00 | LMG95 manual, German or English |
| L95-Z01 | 19″-Mounting kit for LMG95 |
| L95-Z02 | Carrying / tilting handle bar for LMG95 |
| L95-Z03 | Safety claw grip type C, 1 set=4 pcs. 2 pcs. in red, 2 pcs. in black, 20A/1000 |
| L95-Z04 | Carrying case for LMG95/95e and accessories |
| L95-Z06 | HF-summing current transformer with burden resistor |
| for interference free current measurements on discharge lamps | |
| L95-Z06-HV | HF-summing current transformer with burden resistor, |
| standard safety connectors replaced by special high voltage cable, open on both sides, due to insulation (2kV) reasons | |
| (for interference free current measurements on e.g. discharge lamps) | |
| L95-Z07 | Adapter LMG95 external shunt input for the use of hall sensors L45-Z28, -Z29 and compensated current clamp L45-Z406 |
| HD15 female to 2x 4mm safety plug, D-SUB9 cable for supply from LMG95 aux. supply | |
| L50-Z318 | RS232 – Ethernet – converter, 10/100Mbit |
| external adaptor, all connectors will fixed at the LMG, power supply from LMG |