Data Acquisition & Data Loggers
DAQ and Data Logger solutions from Measurement Computing and Data Translation provide for a wide range of applications and interfaces.
USB Data Acquisitions

High-Precision Thermocouple Measurement USB/Ethernet System
TC-32: 32 thermocouple inputs and 40 digital I/O
TC-32 and TC-32-EXP: 64 thermocouple inputs and 80 digital I/O
24-bit resolution
3 S/s/ch sample rate
Supports thermocouple types J, K, R, S, T, N, E, and B
40 digital I/O (80 digital I/O when using TC-32-EXP)
USB and Ethernet interfaces

USB-1208FS-Plus/LS/1408FS-Plus Series features at a glance:
Eight SE/four DIFF analog inputs
12-bit resolution (USB-1208FS-plus & USB-1208LS)
14-bit resolution (USB-1408FS-Plus)
Two analog outputs
16 digital I/O
One counter input
±10 V (Single-ended mode); ±20 V, ±10 V, ±5 V, ±4 V, ±2.5 V, ±2 V, ±1.25 V, ±1 V (Differential mode)

24-Channel Digital I/O USB Devices
The 37-pin connector provides 24 digital I/O, one counter, six ground, and two power connections
The digital I/O port is configured as two 8-bit and two 4-bit ports based on an 82C55 mode 0 emulation
The CTR signal is the input to the 32-bit external event counter
5.5 V max inout voltage

High-Speed Counter / Timer USB Devices
USB-CTR04: Four counter inputs
USB-CTR08: Eight counter inputs
48 MHz maximum input frequency
Software-selectable resolution up to 64-bits
Aggregate scan rate of 8 MB/s
Supports Totalize, Period, Pulse width, and Timing counter input modes
Four independent pulse-width modulation (PWM) timers

Quadrature Encoder USB Device
Eight counter inputs (quadrature/non-quadrature mode)
Simultaneous input and decoding of up to eight incremental quadrature encoders
High-speed pulse counter for general counting applications; multiple counting modes supported
Configurable as single-ended or differential
10 MHz, 16-, 32, 48-bit resolution, ± 12 V input range

24 Channel Solid-State Digital I/O USB device
Mounting rack for 24 solid state relay (SSR) modules (backplane is divided into two groups of eight modules and two groups of four modules)
Onboard switch to configure the module type (input or output) for each module group (you cannot mix input and output modules within a group)
Onboard switch to configure the control logic polarity (active high or low) for each module group

Electromechanical Relay USB Devices
USB-ERB08: Eight single-pole double-throw (SPDT) Form C electromechanical relays directly controlled by digital I/O lines.
USB-ERB24: 24 single-pole double-throw (SPDT) Form C electromechanical relays directly controlled by digital I/O lines.
USB-ERB08: Supports configurations as two banks of four.
USB-ERB24: Supports configurations as two banks of eight and two banks of four

MCC 118/128: Voltage Measurement DAQ HAT
MCC 118: 8 SE 12-bit voltage inputs
MCC 118: 100 kS/s max sample rate (320 kS/s aggregate for stacked boards)
MCC 118: +/-10 V input range
MCC 128: 8 SE/4 DIFF 16-bit voltage inputs
MCC 128: 100 kS/s max sample rate (320 kS/s aggregate for stacked boards)
MCC 128: Multiple input ranges (+/-10 V, +/-5 V, +/-2 V, +/-1 V)